Intermediate structural members for example midrails or screens must be installed when there is no wall or parapet wall at least 21 inches high 29 cfr 1926 502 b 2.
Osha roof ladder requirements 2019.
The following requirements apply to all ladders as indicated including job made ladders.
Occupational safety health.
Under the new regulations a ladder over 24 feet high will require a personal fall arrest system or ladder safety system.
Osha is giving general industry workplaces including warehouses utilities retail and manufacturing some time to transition.
As of november 19th 2036 cages will no longer be accepted as a form of fall protection and all fixed ladders taller than or that extend beyond 24 feet high must use a personal fall arrest system or a ladder safety system.
Why the time gap.
The new regulations change this requirement dramatically.
For a parapet ladder the access level shall be the roof if the parapet is cut to permit passage through the parapet.
Figure d 14 clearances for fixed ladders in wells.
If the parapet is continuous the access level shall be the top of the parapet.
For through ladders the steps or rungs are omitted from the extensions and the side rails are flared to provide not less than 24 inches 61cm and not more than 30 inches 76 cm of clearance.
A ladder that is less than 24 feet high does not require a fall arrest system of any sort.
If you already have a cage attached to a fixed ladder osha will accept its use for the next 19 years.
Previously a fixed ladder with a cage required a landing platform at a maximum interval of 30 feet.
Although a current osha requirement our fall protection inspection teams see ladders that do not pass the simple climbing width regulation of a minimum of 16 inches.
Per osha 1910 23 b 4 ladder rungs steps and cleats have a minimum clear width of 16 inches measured before installation of ladder safety systems for fixed ladders.
Note to paragraph g.
Inside widths of wells must be at least 30 inches 76 cm.
Wells must completely encircle the ladder.
The top rails of a guardrail system must be 39 to 45 inches above the walking working surface 29 cfr 1926 502 b 1.
What about landing platforms.
Inside faces of wells on the climbing side of the ladder must extend between 27 inches 68 cm and 30 inches 76 cm.
When a ladder safety system is provided the maximum clearance between side rails of the extension must not exceed 36 inches 91 cm.
Section 1910 28 establishes the requirements that employers must follow on the use of cages and wells as a means of fall protection.
These are meant to protect climbers as they ascend.
Bottoms of wells above the point of access.
Platforms used with fixed ladders provide a horizontal surface of at least 24 inches by 30 inches 61 cm by 76 cm.